Bobcat 853H Service Manual Page 35

  • Download
  • Add to my manuals
  • Print
  • Page
    / 372
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 34
HYDRAULIC/HYDROSTATIC SYSTEM
Checking And Adding Fluid
Use only recommended fluid in the hydraulic system See
SPECIFICATIONS, Page 9–1 for the correct fluid.
To check the reservoir, use the following procedure:
Put the Bobcat loader on a level surface. Lower the lift
arms and tilt the Bob–Tach fully back.
Stop the engine.
Remove the dipstick [A].
The fluid level must be between the marks on the dipstick.
If fluid is needed, remove the fill cap (Item 1) [B].
Add the fluid as needed to bring the level to the top mark
on the dipstick [A].
Replacing Hydraulic/Hydrostatic Filters
See the SERVICE SCHEDULE, Page 1–3 for the correct
service interval.
Raise the operator cab. (See Page 1–8.)
Use a filter wrench and remove the filter elements (Item
1 & 2) [C].
Clean the surface of the filter housing where the element
seal contacts the housing. Put clean oil on the rubber seal
of the filter element.
Install and hand tighten the filter elements.
NOTE: Before installing the fill cap, make sure the
rubber gasket is installed on the fill cap (Inset
[B].
A
CD–15162
C
CD–10855
1
1
853, 853H Loader
–1–21– Service Manual
B
CD–15161
CD–15135
1
Page view 34
1 2 ... 30 31 32 33 34 35 36 37 38 39 40 ... 371 372